When a CPE sends an empty POST (polling) on a new TCP connection, the
remoteKey (IP:port) differs from the one registered during Inform.
Add StateMachineManager.getHashIdForRemoteIp() to find the device by
IP alone as a fallback, so cwmpDeviceId is resolved and the exchange
is properly stored in the trace (cwmpMethod: Empty, dashed arrow).
After OperationalState, the state machine was marked completed but leftover
tasks in the CWMPTaskQueue (queued by ConfigurationEvaluationState callbacks)
were being served to the CPE on subsequent empty POSTs via the continue()
task fallback path, causing spurious GetParameterNames + SetParameterValues
exchanges after the session officially ended.
Fix: call taskQueue.clearPendingTasksForDevice() in completeMachine() so no
tasks bleed into the next session.
Generated with [Continue](https://continue.dev)
Co-Authored-By: Continue <noreply@continue.dev>
- Fix state machine start timing: don't call start() in startStateMachine,
let the CPE's first empty body trigger the state machine via continue().
This ensures GPN is sent at the correct point in the TR-069 session.
- Add unit tests for reclassifyDeviceFromCatalog (10 tests)
- Add unit tests for MainStateMachine transitions and GPN callbacks (11 tests)
- Test both scenarios: Huawei (GPN supported) and Livebox (GPN unsupported + fallback)
- Fix tr069_trace_service test path assertion (config/ → data/)
- Update steering doc with Livebox bootstrap command